10kV KYN28 High Voltage Switchgear

10kV KYN28 High Voltage Switchgear

Product Description - KYN28-12 medium voltage switchgear is suitable for 3.6/7.2/12kV three-phase AC 50/60Hz power grid, used for receiving and distributing electric energy, and controlling, monitoring and protecting circuits - Rated AC frequency 50Hz/60HZ, maximum working voltage up to 12KV,...
Send Inquiry

Product Description

 

- KYN28-12 medium voltage switchgear is suitable for 3.6/7.2/12kV three-phase AC 50/60Hz power grid, used for receiving and distributing electric energy, and controlling, monitoring and protecting circuits
- Rated AC frequency 50Hz/60HZ, maximum working voltage up to 12KV, maximum working current up to 4000A
- High reliability verified by operation in more than 50 countries and regions around the world
- Mainly used in power receiving and distribution of substations, power plants, power systems and industrial and mining enterprises, and can also be used for frequent starting of high-voltage motors, etc.
- Meets many international standards: IEC60298, IEC6094, GB3906, DL404, DIN.VDE670, etc.

 

Product Parameters

 

Number Project name Unit Parameter Value

1

Rated voltage

KV

12

2

Rated frequency

HZ

50

3

Rated insulation level Lightning impulse withstand voltage

KV

42

1min power frequency withstand voltage

KV

75

4

Main busbar rated current

A

630,1250,1600,2000,2500,3150,4000**

4000﹡﹡

5

Divided busbar rated current

A

630,1250,1600,2000,2500,

3150.4000.**

6

4S thermal stability current (effective value)

KA

20,25,31.5,40

7

Rated dynamic stability current (peak value)

KA

50,63,80,100

8

Protection level The housing is IP4X, and the isolation room and circuit breaker room doors are IP2X when opened.

Note: The short-circuit capacity of the current transformer should be considered separately; when forced air cooling is used, the rated current can reach 4000A.

 

Conditions of Use

 

- Altitude shall not exceed 1000m
- Ambient air temperature shall not be higher than +40 degrees and not lower than -10 degrees
- Relative humidity: daily average value shall not exceed 95%, monthly average value shall not exceed 90%;
- Saturated vapor pressure: daily average value shall not exceed 2.2KPa, monthly average value shall not exceed 1.8KPa
- The inclination with the vertical plane shall not exceed 5°, and the whole set of cabinets shall be relatively flat and meet the (GBJ232-2) standard
- Required to be in a place without severe vibration and impact, where electrical components will not be corroded and there is no conductive dust

 

Ordering Instructions

 

Customers are required to provide the following information:
- Main circuit diagram, primary circuit system diagram and auxiliary circuit control method
- Equipment layout diagram, distribution room layout diagram
- Brand and model of main electrical components of equipment
- Inlet and outlet method. When busbar bridge connection is required between equipment, data such as bus spacing and height from the ground should be provided.
- Other special requirements can be negotiated with our company

 

Hot Tags: 10kv kyn28 high voltage switchgear, China 10kv kyn28 high voltage switchgear manufacturers, suppliers, factory, epc project, 10kV TBB High Voltage Automatic Reactive Power Compensation Device, skid mounted substation, 10kV SVQR Voltage Regulated Automatic Reactive Power Compensation Device, prefabricated substation, 10kV YBM Prefabricated Substation