MNS Low Voltage Draw-out Switchgear

MNS Low Voltage Draw-out Switchgear

There are three types of cabinets: power distribution center cabinet (PC), motor control center cabinet (MCC) and power factor automatic compensation cabinet
Send Inquiry

Product Overview

 

- Based on the technology introduced from ABB in Switzerland, it is improved by Hengfengyou Electric and divided into standard type and economic type
- There are three types of cabinets: power distribution center cabinet (PC), motor control center cabinet (MCC) and power factor automatic compensation cabinet
- Used for power feeding, bus coupling, lighting, motor control and power compensation in low-voltage distribution systems
- Rated AC frequency 50z/60HZ, maximum working voltage up to 660V, maximum working current up to 3150A
- Mainly used in various fields such as substations, industrial and mining enterprises, large power plants, petrochemicals, high-rise buildings, infrastructure, etc.
- Meet many international standards: IEC60439 BS5486 VDE0660, GB7251, NEMAIC2-322, JB/T9661, etc.

 

Product Parameters

 

Name Parameters
Main circuit rated voltage (V)

AC 380(400),(660)

Auxiliary circuit rated voltage (V)

AC 220 380(400)

DC 110 220

Rated frequency (Hz)

50(60)

Rated insulation voltage (v)

660(1000)

Rated current (A) Horizontal busbar

≤6300

Vertical busbar (MCC)

1000

Bus rated short-time withstand current (kA/S)

50, 80

Bus rated short-time peak withstand current (kA/0.1S)

105,176

Power frequency test voltage (V/1min) Main circuit

2500

Auxiliary circuit

1760

Bus Three-phase four-wire system

A,B,C,PEN

Three-phase five-wire system

A,B,C PE N

Protection level

IP30 IP40

Outside dimensions of the cabinet (W*D*H) mm

600~1000*800~1000*2200

 

Conditions of Use

 

- Altitude shall not exceed 2000m
- Ambient air temperature shall not be higher than +40 degrees and not lower than -5 degrees (average temperature within 24 hours shall not be higher than +35 degrees)
- Ambient air humidity shall not exceed 50%, and a higher relative humidity is allowed at low temperature (such as 90% at +20 degrees), and the influence of condensation caused by temperature changes shall be considered
- The inclination with the vertical plane shall not exceed 5°, and the whole set of cabinets shall be relatively flat and meet the (GBJ232-2) standard
- Required to be in a place without severe vibration and impact, where electrical components will not be corroded and there is no conductive dust

 

Ordering Instructions

 

Customers are required to provide the following information:
- Main circuit diagram, primary circuit system diagram and auxiliary circuit control method
- Equipment layout diagram, distribution room layout diagram
- Brand and model of main electrical components of equipment
- Inlet and outlet method. When busbar bridge connection is required between equipment, data such as bus spacing and height from the ground should be provided.
- Other special requirements can be negotiated with our company

 

Hot Tags: mns low voltage draw-out switchgear, China mns low voltage draw-out switchgear manufacturers, suppliers, factory, Skid Substation, 10kV S11series Oil Immersed Distribution Transforme, scb14 dry type transformer, prefabricated substation, 10kV SVR Automatic Step Voltage Regulator, Automatic Step Voltage Regulator