GGD Low Voltage Switchgear

GGD Low Voltage Switchgear

- Used as power receiving, feeding, busbar, lighting, motor control and power compensation in low-voltage power distribution system
- Includes the functions of power center (PC) and motor control center (MCC)
- Rated AC frequency 50Hz/60HZ, maximum working voltage up to 660V, maximum working current up to 3150A
Send Inquiry

Product Description

 

- Used as power receiving, feeding, busbar, lighting, motor control and power compensation in low-voltage power distribution system
- Includes the functions of power center (PC) and motor control center (MCC)
- Rated AC frequency 50Hz/60HZ, maximum working voltage up to 660V, maximum working current up to 3150A
- Mainly used in power distribution places such as industrial parks, urban residential areas, commercial centers, high-rise buildings, etc.
- Meets many international standards: IEC60439, BS5486, VDE0660, GB7251, NEMAIC2-322, JB/T9661, etc.

 

Product Parameters

 

Model

Rated voltage(V)

Rated current(A)

Rated short-circuit breaking current Rated short circuit tolerance current Rated peak allowable current

GGD-1000-15

380

1000

15

15

30

600(630)

400

GGD-1600-30

380

1500(1600)

30

30

63

1000

600

GGD-3150-50

380

3150

50

50

105

2500

2000

 

Conditions of Use

 

- Altitude shall not exceed 2000m
- Ambient air temperature shall not be higher than +40 degrees and not lower than -5 degrees (average temperature within 24 hours shall not be higher than +35 degrees)
- Ambient air humidity shall not exceed 50%, and a higher relative humidity is allowed at low temperature (such as 90% at +20 degrees), and the influence of condensation caused by temperature changes shall be considered
- The inclination with the vertical plane shall not exceed 5°, and the whole set of cabinets shall be relatively flat and meet the (GBJ232-2) standard
- It is required to be in a place without severe vibration and impact, where electrical components will not be corroded and there is no conductive dust

 

Ordering Instructions

 

Customers are required to provide the following information:
- Main circuit diagram, primary circuit system diagram and auxiliary circuit control method
- Equipment layout diagram, distribution room layout diagram
- Brand and model of main electrical components of equipment
- Inlet and outlet method. When busbar bridge connection is required between equipment, data such as bus spacing and height from the ground should be provided.
- Other special requirements can be negotiated with our company

 

Hot Tags: ggd low voltage switchgear, China ggd low voltage switchgear manufacturers, suppliers, factory, Solar Power Box Type Substation, high and low voltage switchgear, vehicle mounted mobile substation, prefabricated substation manufacturers, Wind Power Box Type Substation, 10kV YBM Mobile Prefabricated Substation