Product Overview
KYN61-40.5 is a medium and high voltage switchgear engineered for efficient power receiving, distribution, control, monitoring, and circuit protection. It is widely applied in substations, power plants, power grids, and industrial & mining enterprises. Additionally, it supports frequent starting of high-voltage motors, meeting the diverse needs of industrial power systems.Key Advantages:
Broad Application Scope: Suitable for power systems in multiple industries, with strong adaptability.
High Safety & Reliability: Complies with international standards (IEC60298, IEC6094, GB3906, DL404, DIN.VDE670) to ensure stable operation.
Excellent Performance: Adapts to 50Hz/60Hz rated frequency, with a maximum working voltage of 40.5KV and maximum working current up to 4000A.
Product Parameters
| Item | Unit | Parameter | |
| Rated voltage |
kV |
40.5 |
|
| Rated insulation level | Lightning strike voltage (full wave) |
kV |
185 |
| Power frequency withstand voltage (1min) |
kV |
95 |
|
| Rated frequency |
Hz |
50 |
|
| Rated current |
A |
630;1250;1600;2000 |
|
| Rated circuit-breaking time | Power frequency withstand voltage (1min) |
kV |
20,25,31.5 |
| Rated short-circuit closing current (peak value) |
kV |
50,63,80 |
|
| Rated dynamic steady current (peak value) |
kV |
50,63,80 |
|
| 4S thermal stability current (effective value) |
kV |
20,25,31.5 |
|
| Enclosure protection grade | Vacuum circuit breaker cabinet |
mm |
IP4X |
| Dimensions (W×D×H) |
mm |
1400×2800×2600 |
|
Conditions of use
To ensure optimal performance, the KYN61-40.5 high voltage switchgear should be used under the following conditions:
Altitude: ≤1000m
- Ambient temperature: -10℃ ~ +40℃
- Relative humidity: Daily average ≤95%, monthly average ≤90%
- Saturated vapor pressure: Daily average ≤2.2KPa, monthly average ≤1.8KPa
- Installation inclination: ≤5° from the vertical plane; the cabinet set shall be flat and comply with GBJ232-2 standard
- Environment: No severe vibration, impact, corrosive substances, or conductive dust
Ordering instructions
When placing an order for the KYN61-40.5 35kV high voltage switchgear, customers are required to provide the following information for customized production:
- Electrical diagrams: Main circuit schematic, primary circuit system diagram, and auxiliary circuit control method
- Layout drawings: Equipment layout diagram and distribution room layout diagram
- Component requirements: Brand and model of main electrical components
- Connection details: Inlet/outlet line mode; if busbar bridge connection is required between equipment, provide busbar spacing, ground height, and other relevant data
- Special requirements: Customized needs can be negotiated with Sefon Electric's technical team
Hot Tags: 35kv kyn61 high voltage switchgear, China 35kv kyn61 high voltage switchgear manufacturers, suppliers, factory, Dry Type Transformer, s13series oil immersed distribution transforme, 35kV KYN61 High Voltage Switchgear, Wind Power Box Type Substation, 10kV SVQR Voltage Regulated Automatic Reactive Power Compensation Device, European Style Box Type Substation